Previous Page  180 / 242 Next Page
Information
Show Menu
Previous Page 180 / 242 Next Page
Page Background

T. Lording, S. Lustig, P. Neyret

180

[7] Denham RA, Bishop RE. Mechanics of the knee and

problems in reconstructive surgery.

J Bone Joint Surg Br.

1978; 60(3): 345-52.

[8] Hvid I, Nielsen S. Total condylar knee arthroplasty:

prosthetic component positioning and radiolucent lines.

Acta

Orthop 1984; 55(2): 160-5. doi:10.1016/j.arth.2013.11.018.

[9] Bargren JH, BlahaJD, FreemanMA.Alignment

in total knee arthroplasty. Correlated biomechanical and

clinical observations.

Clin Orthop Relat Res. 1983; (173):

178-83.

[10] Jeffery RS, Morris RW, Denham RA. Coronal

alignment after total knee replacement.

J Bone Joint Surg Br.

1991; 73(5): 709-14.

[11] Ritter MA, Faris PM, Keating EM, Meding

JB. Postoperative alignment of total knee replacement its

effect on survival.

Clin Orthop Relat Res. 1994; 299: 153-6.

[12] D’Lima DD, Hermida JC, Chen PC, Colwell

CW J

r

Polyethylene wear and variations in knee kinematics.

Clin Orthop Relat Res. 2001; 392: 124-30.

[13] D’Lima DD, Chen PC, Colwell CW J

r

Polyethylene contact stresses, articular congruity, and knee

alignment.

Clin Orthop Relat Res. 2001; 392: 232-8.

[14] Liau JJ, Cheng CK, Huang CH, Lo WH. The

effect of malalignment on stresses in polyethylene component

of total knee prostheses – a finite element analysis.

Clin

Biomech. 2002; 17(2): 140-6.

[15] Green GV, Berend KR, Berend ME, Glisson

RR, Vail TP. The effects of varus tibial alignment on

proximal tibial surface strain in total knee arthroplasty: The

posteromedial hot spot.

J Arthroplasty. 2002; 17(8): 1033-9.

[16] Berend ME, Ritter MA, Meding JB,

et al.

The

Chetranjan Ranawat Award: Tibial Component Failure

Mechanisms in Total Knee Arthroplasty.

Clin Orthop Relat

Res. 2004; 428: 26-34.

[17] Werner FW, Ayers DC, Maletsky LP,

Rullkoetter PJ. The effect of valgus/varus

malalignment on load distribution in total knee replacements.

J Biomech. 2005; 38(2): 349-55.

[18] Collier MB, Engh Jr CA, McAuley JP, Engh

GA. Factors associated with the loss of thickness of

polyethylene tibial bearings after knee arthroplasty.

J Bone

Joint Surg Am. 2007; 89(6): 1306-14.

[19] Morgan SS, Bonshahi A, Pradhan N,

Gregory A, Gambhir A, Porter ML. The influence

of postoperative coronal alignment on revision surgery in

total knee arthroplasty.

Int Orthop 2007; 32(5): 639-42.

[20] Parratte S, Pagnano MW, Trousdale RT,

Berry DJ. Effect of postoperative mechanical axis

alignment on the fifteen-year survival of modern, cemented

total knee replacements.

J Bone Joint Surg Am. 2010; 92(12):

2143-9.

[21] Matziolis G, Adam J, Perka C. Varus

malalignment has no influence on clinical outcome in

midterm follow-up after total knee replacement.

Arch Orthop

Trauma Surg. 2010; 130(12): 1487-91.

[22] Magnussen RA, Weppe F, Demey G, Servien

E, LustigS. Residual varus alignment does not compromise

results of TKAs in patients with preoperative varus.

Clin

Orthop Relat Res. 2011; 469: 3443-50.

[23] Vanlommel L, Vanlommel J, Claes S,

Bellemans J. Slight undercorrection following total

knee arthroplasty results in superior clinical outcomes in

varus knees.

Knee Surg Sports Traumatol Arthrosc. 2013;

21(10): 2325-30.

[24] Choong PF, Dowsey MM, Stoney JD. Does

accurate anatomical alignment result in better function and

quality of life? Comparing conventional and computer-

assisted total knee arthroplasty.

J Arthroplasty 2009; 24(4):

560-9.

[25] Longstaff LM, Sloan K, Stamp N, Scaddan

M, Beaver R. Good alignment after total knee arthroplasty

leads to faster rehabilitation and better function.

J Arthroplasty. 2009; 24(4): 570-8.

[26] Blakeney WG, Khan RJK, Palmer JL.

Functional outcomes following total knee arthroplasty: A

randomised trial comparing computer-assisted surgery with

conventional techniques.

Knee 2014; 21(2): 364-8.

[27] Schmitt J, Hauk C, Kienapfel H,

et al.

Navigation of total knee arthroplasty: rotation ofcomponents

and clinical results in a prospectivelyrandomized study.

BMC Musculoskelet Disord. 2011; 12(1): 16.

[28] Harvie P, Sloan K, Beaver RJ. Computer

navigation vs conventional total knee arthroplasty: five-year

functional results of a prospective randomized trial.

J Arthroplasty. 2012; 27(5): 667-72.e1.

[29] Lad D, Thilak J, Thadi M. Component alignment

and functional outcome following computer assisted and

jig based total knee arthroplasty.

Indian J Orthop. 2013;

47(1): 77.

[30] L

J, Dexel J, Kirschner S. No difference

between computer-assisted and conventional total knee

arthroplasty: five-year results of a prospective randomised

study.

Knee Surg Sports Traumatol Arthrosc. 2013; 21(10):

2241-7.

[31] Burnett RSJ, Barrack RL. Computer-assisted

Total Knee Arthroplasty Is Currently of No Proven Clinical

Benefit: A Systematic Review.

Clin Orthop Relat Res. 2012;

471: 264-76.

[32] Rebal BA, Babatunde OM, Lee JH, Geller

JA, Patrick DA, Macaulay W. Imageless computer

navigation in total knee arthroplasty provides superior short

term functional outcomes: a meta-analysis.

J Arthroplasty.

2014; 29(5): 938-44.