Previous Page  38 / 76 Next Page
Information
Show Menu
Previous Page 38 / 76 Next Page
Page Background

38

//

MAITRISE ORTHOPEDIQUE

Bibliographie

1. S. A. Eisenhuth, K. J. Saleh, Q. Cui, C. R. Clark, et T. E. Brown,

« Patellofemoral instability after total knee arthroplasty »,

Clin. Orthop.,

vol. 446, p. 149‑160, mai 2006.

2. S. J. Song, R. C. Detch, W. J. Maloney, S. B. Goodman, et J. I. Huddleston,

« Causes of Instability After Total Knee Arthroplasty »,

J.

Arthroplasty, vol. 29, no 2, p. 360‑364, févr. 2014.

3. C. S. Ranawat,

« The patellofemoral joint in total condylar knee arthroplasty. Pros and cons based on five- to ten-year follow-up observations »,

Clin.

Orthop., no 205, p. 93‑99, avr. 1986.

4. M. Malo et K. G. Vince,

« The unstable patella after total knee arthroplasty: etiology, prevention, and management »,

J. Am. Acad. Orthop. Surg., vol.

11, no 5, p. 364‑371, oct. 2003.

5. J. Luo, C. Yu, J. Qin, et D. Xu,

« [Rotational malalignment causing patellofemoral complications after total knee replacement] »,

Nan Fang Yi Ke Da

Xue Xue Bao, vol. 26, no 2, p. 217‑219, févr. 2006.

6. A. M. Merican, K. M. Ghosh, F. Iranpour, D. J. Deehan, et A. A. Amis,

«

The effect of femoral component rotation on the kinematics of

the tibiofemoral and patellofemoral joints after total knee arthroplasty »,

Knee Surg. Sports Traumatol. Arthrosc. Off. J. ESSKA, vol. 19, no 9, p.

1479‑1487, sept. 2011.

7. U. G. Longo, M. Ciuffreda, N. Mannering, V. D’Andrea, M. Cimmino, et V. Denaro,

« Patellar Resurfacing in Total Knee Arthroplasty:

Systematic Review and Meta-Analysis »,

J. Arthroplasty, vol. 33, no 2, p. 620‑632, févr. 2018.

8. 

« The management of extensor mechanism complications in total knee arthroplasty.

AAOS exhibit selection. - PubMed - NCBI ». [En ligne]

9. J. L. Briard et D. S. Hungerford,

« Patellofemoral instability in total knee arthroplasty »,

J. Arthroplasty, vol. 4 Suppl, p. S87-97, 1989.

10. F. Franck, H. Ouanezar, A. Jacquel, V. Pibarot, et J. Wegrzyn,

« The predictive factors of secondary patellar resurfacing in computer-assisted

total knee arthroplasty. A prospective cohort study »

, Int. Orthop., sept. 2017.

11. R. A. Berger, L. S. Crossett, J. J. Jacobs, et H. E. Rubash,

« Malrotation causing patellofemoral complications after total knee arthroplasty »,

Clin. Orthop., no 356, p. 144‑153, nov. 1998.

12. R. Philippot, B. Boyer, R. Testa, F. Farizon, et B. Moyen,

« The role of the medial ligamentous structures on patellar tracking during knee flexion

»,

Knee Surg. Sports Traumatol. Arthrosc., vol. 20, no 2, p. 331‑336, févr. 2012.

13. S. Asada, M. Akagi, S. Mori, et C. Hamanishi,

« Medial patellofemoral ligament reconstruction for recurrent patellar dislocation after total knee

arthroplasty »,

J. Orthop. Sci., vol. 13, no 3, p. 255‑258, mai 2008.

14. M. W. Pagnano, R. T. Trousdale, M. J. Stuart, A. D. Hanssen, et D. J. Jacofsky,

« Rotating platform knees did not improve patellar tracking:

a prospective, randomized study of 240 primary total knee arthroplasties »,

Clin. Orthop., no 428, p. 221‑227, nov. 2004.

15. R. L. Merkow, M. Soudry, et J. N. Insall,

« Patellar dislocation following total knee replacement »,

J. Bone Joint Surg. Am., vol. 67, no 9, p.

1321‑1327, déc. 1985.

16. P. Kirk, C. H. Rorabeck, R. B. Bourne, B. Burkart, et L. Nott,

« Management of recurrent dislocation of the patella following total knee

arthroplasty »,

J. Arthroplasty, vol. 7, no 3, p. 229‑233, sept. 1992.

17. D. F. Bindelglass, J. L. Cohen, et L. D. Dorr,

« Patellar tilt and subluxation in total knee arthroplasty. Relationship to pain, fixation, and design

»,

Clin. Orthop., no 286, p. 103‑109, janv. 1993.

18. W. Petersen et al.,

« Anterior knee pain after total knee arthroplasty: a narrative review »,

Int. Orthop., vol. 38, no 2, p. 319‑328, févr. 2014.

19. A. Keshmiri, F. Dotzauer, C. Baier, G. Maderbacher, J. Grifka, et E. Sendtner,

« Stability of capsule closure and postoperative anterior knee

pain after medial parapatellar approach in TKA »,

Arch. Orthop. Trauma Surg., vol. 137, no 7, p. 1019‑1024, juill. 2017.

20. E. Servien et al.,

« In vivo positioning analysis of medial patellofemoral ligament reconstruction »,

Am. J. Sports Med., vol. 39, no 1, p. 134‑139,

janv. 2011.

21. T. Goto et al.,

« Medial patellofemoral ligament reconstruction for patellar dislocation due to rupture of the medial structures after total knee arthroplasty: a

case report and review of the literature »,

J. Med. Investig. JMI, vol. 61, no 3‑4, p. 409‑412, 2014.

22. S. van Gennip, J. J. P. Schimmel, G. G. van Hellemondt, K. C. Defoort, et A. B. Wymenga,

« Medial patellofemoral ligament

reconstruction for patellar maltracking following total knee arthroplasty is effective »,

Knee Surg. Sports Traumatol. Arthrosc. Off. J. ESSKA, vol. 22, no

10, p. 2569‑2573, oct. 2014.

23. A. Lamotte, T. Neri, A. Kawaye, B. Boyer, F. Farizon, et R. Philippot,

« Medial patellofemoral ligament reconstruction for patellar instability

following total knee arthroplasty: A review of 6 cases »,

Orthop. Traumatol. Surg. Res. OTSR, vol. 102, no 5, p. 607‑610, 2016.

Ensuite, la série de Gennip et

al.

[22]

, décrit 9 cas de recons-

truction du MFPL associée à

une libération latérale systéma-

tique, et deux transpositions de

la TTA. Ils utilisaient le tendon

quadricipital lorsque celui-ci

était en bon état, sinon ils pré-

féraient utiliser une allogreffe

tendineuse fixée au moyen de

deux ancres. Un suivi médian

de 33 mois n’a pas mis en évi-

dence de nouvelle luxation.

Lamotte et al.

[23]

ont quant à

eux décrit 6 cas de reconstruc-

tion du MPFL utilisant une

autogreffe au gracilis, fixé par

2 ancres. Une reconstruction

était associée au changement

de prothèse (rotation interne

cumulée à 8°). Aucun des

patients n’a présenté de nou-

velle luxation et tous ont amé-

lioré leurs scores clinques.

Cette dernière série décrit aussi

le cas particulier d’un patient

de 81 ans aux lourds antécé-

dents médicaux qui présentait

une luxation permanente de la

rotule sur une rotation interne

fémorale de 7°. La révision

prothétique étant jugée trop

risquée, une reconstruction du

MPFL a été réalisée. Une insta-

bilité subjective persistait mais

aucune nouvelle luxation n’est

survenue.

Cette utilisation « palliative » et

peu consensuelle de la recons-

truction du MPFL, la rend

intéressante car peu morbide,

elle peut apporter une solution

simple chez des patients dont

les révisions sont difficilement

envisageables et dont le béné-

fice fonctionnel attendu est

faible.

C

onclusion

La reconstruction du MPFL

pour les instabilités rotuliennes

sur PTG est un des outils à

notre disposition, parmi un

arsenal de thérapeutiques per-

mettant de recentrer la rotule

dans des indications choisies.

Nous l’utilisons presqu’exclu-

sivement associée à d’autres

gestes, osseux ou sur les

parties molles.

g

MISE AU POINT